specifications subject to change without notice. dimensions (mm). 3 phase, 4 wire chassis mount emi/rfi line filter. pe3p4w series mechanical dimensions features the pe3p4w series filters have been designed for heavy-duty machinery that requires noise control. the filters offer good noise attenuation in both forward and reverse directions for common mode and differential mode. these filters are designed with high reliability for industrial equipment. this series offers filters up to 250a at 250vac/500vac with suppression from 150khz to 30mhz. applications heavy industry equipment, measuring & control equipment, power supplies, other electronic/electrical equipment. (unit: mm) g2a c5 140.0 65.0 35.0 164.0 184.0 2x 10 m6 typ. 126.4 170.0 201.0 92.0 2x 10x14 77.0 54.0 14.0 34.0 2x r5x 10 90.6 100.0 2x 5.0 m6 typ. 84.0 112.0 143.0 30 60 100 (379.8) 300 44 44 44 200 300 347 m12 typ. 2x 10.5x13.5 180 2x 11 g3a 55 145 algonquin parkway, whippany, nj 07981 ? 973-560-0019 ? fax: 973-560-0076 e-mail: filtersales@powerdynamics.com ? www.powerdynamics.com
non-medical applications schematic 1; case g2a pe3p4w series non-medical applications schematic 2; case g3a insertion loss in db (50 ohm circuit) non-medical applications non-medical applications insertion loss in db (50 ohm circuit) technical data ? rated voltage: 500vac ? rated current: 10a, 20a ? power line frequency: 50/60hz ? max. leakage current each line to ground: @ 500vac, 60hz: 1ma (10a) @ 500vac, 60hz: 4ma (20a) ? hipot rating (one minute) line to ground: 2250vdc ? temperature range: -25c to +50c technical data ? rated voltage: 500vac ? rated current: 20a, 30a, 60a ? power line frequency: 50/60hz ? max. leakage current each line to ground: @ 500vac, 60hz: 7.5ma ? hipot rating (one minute) line to ground: 2250vdc ? temperature range: -25c to +50c e l1 l2 l3 n l l l line cx cx cx cy l'1 l'2 n' l'3 load l1 l2 l3 n load line l'1 l'2 l'4 l'3 l1 l1 l1 c 1 r c 1 r r c 1 e lg cy cy cy cy cy cy cy cy c 2 c 2 c 2 pdi cx cy l comm. mode (l-g) in mhz diff. mode (l-l) in mhz p/n (uf) (pf) (mh x 2) .15 .5 1 5 10 30 .15 .5 1 5 10 30 pe3p4w-10ps-1-g2a 0.1 4700 0.2 12 22 22 22 32 27 12 16 22 37 42 27 pe3p4w-20ps-1-g2a 22000 0.12 12 22 27 27 32 32 12 17 22 22 27 22 current rating (a) 10 20 current rating (a) 20 30 60 pdi cx1 cx2 cy l r comm. mode (l-g) in mhz diff. mode (l-l) in mhz p/n (uf) (uf) (pf) (mh x 2) (ohms) .15 .5 1 5 10 30 .15 .5 1 5 10 30 pe3p4w-20ps-2-g3a 3.2 39 55 56 65 65 54 50 65 65 65 60 52 pe3p4w-30ps-2-g3a 2 1 4700 1.6 110k 30 55 55 61 63 60 43 65 66 65 58 49 PE3P4W-60PS-2-G3A 0.32 22 50 50 54 54 47 27 60 64 64 56 50 56 145 algonquin parkway, whippany, nj 07981 ? 973-560-0019 ? fax: 973-560-0076 e-mail: filtersales@powerdynamics.com ? www.powerdynamics.com
technical data ? rated voltage: 500vac ? rated current: 60a, 80a, 100a, 150a, 200a, 250a ? power line frequency: 50/60hz ? max. leakage current each line to ground: @ 500vac, 60hz: 2.6ma (60a, 80a) @ 500vac, 60hz: 7.5ma (100a) @ 500vac, 60hz: 8.0ma (150a, 200a, 250a) ? hipot rating (one minute) line to ground: 2250vdc ? temperature range: -25c to +50c pe3p4w series schematic 3; case c5 non-medical applications non-medical applications insertion loss in db (50 ohm circuit) pdi r cx1,2 cy l comm. mode (l-g) in mhz diff. mode (l-l) in mhz p/n (ohms) (uf) (pf) (mh x 2) .15 .5 1 5 10 30 .15 .5 1 5 10 30 pe3p4w-60ps-3-c5 1.00 3300 0.8 38 42 54 56 47 32 78 73 63 48 51 31 pe3p4w-80ps-3-c5 2.20 3300 0.4 42 48 53 49 56 45 75 65 68 54 43 32 pe3p4w-100ps-3-c5 430k 2.20 4700 0.1 37 53 59 53 52 43 81 75 63 52 39 27 pe3p4w-150ps-3-c5 3.30 10000 0.06 35 56 63 54 48 32 85 72 58 54 45 29 pe3p4w-200ps-3-c5 3.30 10000 0.02 32 53 61 58 51 28 82 78 65 53 41 25 pe3p4w-250ps-3-c5 3.30 10000 0.015 30 57 60 63 49 27 83 78 68 51 43 28 c 1 e l1 l2 r l3 n c 1 r r c 1 l1 l1 l1 l2 l2 l2 c 2 c 2 load line l'1 l'2 l'4 l'3 cy cy cy cy c 2 current rating (a) 60 80 100 150 200 250 57 145 algonquin parkway, whippany, nj 07981 ? 973-560-0019 ? fax: 973-560-0076 e-mail: filtersales@powerdynamics.com ? www.powerdynamics.com
|